Bushing insulators are designed to provide electrical connections between circuits through the chambers of an enclosure or partition while ensuring electrical insulation. Bushing insulators are used in electric motors, pumps, transformers, switchgear, and electrical equipment. Bushing insulators consist of copper through-pins positioned along the axis of a brass sleeve with a thrust flange, effectively electrically insulated by insulating materials placed between them.

I M2 Ex db eb I Mb

II 2G Ex db eb IIC Gb

 

Ask for the product

Bushing insulator type D:

Rated voltage: 1250V

Rated current: 100A – 500A

Working temperature: -45oC to +120oC

Relative humidity of air [40°C]: 95%

Corrosivity category C5 according to PN-EN ISO 12944-2

I M2 Ex db eb I Mb; II 2G Ex db eb IIC Gb

PN-EN IEC 60079-0:2018, equivalent to IEC 60079-0:2017; PN-EN 60079-1:2014, equivalent to IEC 60079-1:2014; PN-EN 60079-7:2016, equivalent to IEC 60079-1:2015

Parameters of D..-M36(C35) insulators

Insulator type 

Current-carrying capacity 

Insulator pin ends 

External thread M1 

Threaded hole M2 

D8-M36 

 

100A 

M8 

- 

D8-C35 

M8 

- 

D8/6..-M36 

M8 

M6 

D8/6..-C35 

M8 

M6 

 

D10-M36 

 

 

 

160A 

M10 

- 

D10-C35 

M10 

- 

D10/6..-M36 

M10 

M6 

D10/6..-C35 

M10 

M6 

D10/8..-M36 

M10 

M8 

D10/8..-C35 

M10 

M8 

Dw6-M36 

- 

M6 

Dw6-C35 

- 

M6 

 

D12-M36 

 

 

 

250A 

M12 

- 

D12- C35 

M12 

- 

D12/8..-M36 

M12 

M8 

D12/8..- C35 

M12 

M8 

D12/10..-M36 

M12 

M10 

D12/10..- C35 

M12 

M10 

Dw8-M36 

- 

M8 

Dw8- C35 

- 

M8 

 

D16-M36 

 

 

400A 

M16 

- 

D16- C35 

M16 

- 

D16/12..-M36 

M16 

M12 

D16/12..- C35 

M16 

M12 

Dw10-M36 

- 

M10 

Dw10- C35 

- 

M10 

 

D18-M36 

 

 

500A 

M18 

- 

D18- C35 

M18 

- 

D18/10..-M36 

M18 

M10 

D18/10..- C35 

M18 

M10 

Dw10-M36 

- 

M10 

Dw10- C35 

- 

M10 

Parameters of D..-M42(C40) insulator

Insulator type 

Current carrying-capacity 

Insulator pin ends 

External thread M1 

Threaded hole M2 

D8-M42 

 

100A 

M8 

- 

D8-C40 

M8 

- 

D8/6..-M36 

M8 

M6 

D8/6..-C35 

M8 

M6 

 

D10-M42 

 

 

 

160A 

M10 

- 

D10-C40 

M10 

- 

D10/6..-M42 

M10 

M6 

D10/6..-C40 

M10 

M6 

D10/8..-M42 

M10 

M8 

D10/8..-C40 

M10 

M8 

Dw6-M42 

- 

M6 

Dw6-C40 

- 

M6 

 

D12-M42 

 

 

 

250A 

M12 

- 

D12- C40 

M12 

- 

D12/8..-M42 

M12 

M8 

D12/8..- C40 

M12 

M8 

D12/10..-M42 

M12 

M10 

D12/10..- C40 

M12 

M10 

Dw8-M42 

- 

M8 

Dw8- C40 

- 

M8 

 

D16-M42 

 

 

400A 

M16 

- 

D16- C40 

M16 

- 

D16/12..-M42 

M16 

M12 

D16/12..- C40 

M16 

M12 

Dw10-M42 

- 

M10 

Dw10- C40 

- 

M10 

 

D18-M42 

 

 

500A 

M18 

- 

D18- C40 

M18 

- 

D18/10..-M42 

M18 

M10 

D18/10..- C40 

M18 

M10 

Dw10-M42 

- 

M10 

Dw10- C40 

- 

M10 

in